Modbus to BACnet Protocol Gateway is a device used to implement communication conversion between Modbus networks and BACnet networks. It provides efficient solutions for building automation, industrial control, energy management and other fields.
Communication
Ethernet, WiFi
Downlink Protocol
Modbus RTU, Modbus TCP
Uplink Protocol
BACnet MS/TP, BACnet/IP
Serial Port
2CH or 6CH RS485/RS232
Baud Rate
2400bps-115200bps
Ethernet Port
1 WAN + 1 LAN
Description

Modbus to BACnet Gateway

BA100 Series · Bridge legacy Modbus devices to modern BACnet BMS systems

2 or 6 serial ports 4,000 data points BACnet/IP · BACnet MS/TP -40~85°C wide temp Optional WiFi
🏢
BA100 2‑Port BA100P 6‑Port
Supports 10–50 devices · 512–4,000 data points · Optional WiFi
⬇ Modbus RTU/TCP ⬆ BACnet/IP & MS/TP
📡 WiFi 🔌 Ethernet

📊 BA100 vs BA100P – Side‑by‑Side

Choose BA100 for cost‑efficient small building zones, or BA100P for high‑density data acquisition across large facilities. Both support optional WiFi.

Feature BA100 (Standard) BA100P (High‑Performance)
Serial Channels 2 × RS485/RS232 6 × RS485/RS232
Max. Devices 10 50
Data Points 512 4,000
Downlink Protocols Modbus RTU · Modbus TCP Modbus RTU · Modbus TCP
Uplink Protocols BACnet/IP · BACnet MS/TP BACnet/IP · BACnet MS/TP
WiFi (Optional) 802.11a/b/g/n 802.11a/b/g/n
Dimensions (L×W×H) 30 × 83 × 110 mm 40 × 83 × 110 mm
Weight 133 g 171 g
Best Fit Small Buildings / Zones Large Facilities / Campuses
💡 Quick rule: ≤ 10 devices → BA100  |  > 10 devices → BA100P  |  📡 WiFi available for both models
⚡ CUSTOMER VALUE

Bridge Modbus Devices to BACnet BMS Systems

  • Seamless Protocol Conversion
    Native conversion from Modbus RTU/TCP to BACnet/IP and BACnet MS/TP — no middleware or scripting required.
  • Rapid BMS Integration
    Connect HVAC, energy meters, sensors, and controllers to any BACnet-compliant BMS — Siemens, Honeywell, Johnson Controls, Schneider, and more.
  • Zero On‑Site Maintenance
    Remote configuration, firmware upgrades, and system monitoring — significantly reduces travel costs and response time.
🏭 -40°C ~ 85°C 🛡️ EMC Level 3 🔒 2KV Isolation

📡 TYPICAL DATA FLOW ARCHITECTURE

HVAC / Energy Meter / Sensor / PLC
Modbus RTU/TCP
BA100 / P
Modbus → BACnet
🔌 ETH📡 WiFi
BACnet/IP BACnet MS/TP BMS
Building Management System

🚀 Core Advantages

Engineered for building automation reliability and seamless IT/OT convergence.

🔄

Native BACnet Conversion

Downlink Modbus RTU/TCP Master, uplink BACnet/IP and BACnet MS/TP — native protocol conversion without additional gateways or software.

🏗️

BMS‑Ready Integration

Works seamlessly with all major BMS platforms — Siemens Desigo, Honeywell Niagara, Johnson Controls Metasys, Schneider Electric EcoStruxure, and more.

📶

Flexible Connectivity

Ethernet or optional WiFi — deploy in existing building networks without additional cabling. Remote access via OpenVPN.

🏭

Industrial‑Grade Durability

9–36V DC wide input, reverse‑polarity protection, -40~85°C operation, EMC Level 3 (ESD/EFT/Surge), 2KV isolation.

🌐

Remote Lifecycle Management

Full remote configuration, firmware upgrades, and diagnostics — eliminate costly on‑site visits for building maintenance.

🔧

Flexible Mounting

DIN35 rail or wall mounting with patented rail‑clip — quick installation in electrical panels and equipment rooms.

📋 Technical Specifications

Click a tab below for detailed module parameters. Both models share the same core platform.

System & Power Serial & Ethernet WiFi (Optional) Environment & Cert.
ProcessorARM MCU, 300MHz
Storage128MB Storage · 64MB Flash
Input VoltageDC 9~36V (wide range)
Power Consumption70mA@12V (typ) · 168mA@12V (max)
ProtectionReverse‑polarity protection
WatchdogHW + SW dual watchdog (auto‑reboot < 3s)
USB2× Micro (OTG), over‑current protection
ProtocolsModbus RTU/TCP · BACnet/IP · BACnet MS/TP
* Full details in the product datasheet

🏢 Typical Applications

Trusted by building system integrators and facility managers across industries.

❄️

HVAC Building Automation

Connect chillers, AHUs, VAV boxes, and thermostats to BACnet BMS for centralized control and monitoring.

🏢

Smart Building Management

Unify lighting, access control, and environmental sensors into a single BACnet-based management platform.

Energy Monitoring System

Collect energy data from Modbus power meters, sub‑meters, and solar inverters for BACnet EMS integration.

🏭

Industrial Facility Management

Bridge Modbus PLCs and industrial sensors to BACnet for facility-wide monitoring and control.

  • Modbus to BACnet Gateway
  • Modbus to BACnet Gateway
  • Modbus to BACnet Gateway
  • Modbus to BACnet Gateway
  • Modbus to BACnet Gateway

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
Leave a message
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.